Health Service Configuration Not Up To Date

If you get an alert similar to this.

Alert: Health Service Configuration Not Up To Date
Source: myserver.contoso.com
Path: myserver.contoso.com
Last modified by: System
Last modified time: 8/11/2007 10:30:14 AM Alert description: The Health Service has requested new configuration, but no has not received it for more than 90 minutes.

The problem is that the Windows firewall is running on the server that you installed the agent on and it is not communicating properly to the Management Server.

Resolution is to open up port 5724

5 Responses to Health Service Configuration Not Up To Date

  1. schmittchen.schleicher August 17, 2007 at 1:13 pm #

    Leider ist dem nicht ganz so. Ich bekomme auch diese Fehlermeldung, allerdings ist die Windows Firewall auf den entsprechenden Servern deaktiviert. FΓΌr weitere Tips bin ich sehr dankbar πŸ™‚

  2. schmittchen.schleicher August 17, 2007 at 1:17 pm #

    Sorry, forgot to write in english πŸ˜‰

    The hint doesn’t work for me. The windows firewall is disabled on the affected servers. I’ll be glad for any tips πŸ™‚

  3. Ali August 20, 2007 at 9:51 am #

    Same for me, firewall is not installed on the server, the service is disabled. But yet I still get this error as well.

    Thanks
    Ali

  4. FunkeyMonkey February 18, 2008 at 5:52 am #

    Anyone got a resolution to this yet ?

  5. smeeta February 22, 2008 at 1:39 am #

    Solution:
    Check if the OpsMgr config service is running on the SCOM server. Restart the service.
    I am sure this will help resolving the issue…

Leave a Reply